Typical  Accuracy  =  +/-  0.01%
Worst  Case  =  +/-  0.04%
OVERVIEW
PRODUCT  HIGHLIGHTS:  The  Radian  RD-20  Single-phase  Electricity  Reference  Standard  is  one  of  the  most  versatile  reference  instruments  ever.  The  RD-20  has  a  typical  accuracy  of  0.01%  for  all  measurement  functions  across  its  entire  operating  range,  with  a  maximum  worst  case  accuracy  of  0.04%.  This  worst  case  accuracy  specification  includes  the  variables  of  stability,  power  factor,  traceability  uncertainty  and  test  system  errors.
The  RD-20  utilizes  Radian's  new  Dytronic  measurement  technology  consisting  of  a  Radian  designed  Integrating  Analog  to  Digital  Signal  Converter.Unlike  off-the-shelf  A/D  Converters  used  in  other  instruments,  Radian¡¯s  A/D  Converter  is  specifically  designed  and  optimized  for  power  and  energy  measurement.  This  unique  design  makes  the  RD-20  absolutely  unsurpassed  in  its  ability  to  accurately  measure  ¡°real  world¡±  waveforms.  The  RD-20¡¯s  A/D  Converter  is  combined  with  Radian¡¯s  renowned  electronically  compensated  voltage  and  current  input  transformers  and  a  hermetically  sealed  reference  set  to  provide  the  highest  degree  of  accuracy,  stability  and  versatility  offered  in  a  portable  single-phase  standard.
MEASUREMENTS:The  RD-20  is  a  four  quadrant  single-phase,  simultaneous  measuring  instrument  that  registers  both  forward  and  reverse  energy  flow  and  provides  voltage,  current,  power  and  energy  (Active,  Reactive,  Apparent)  information.  The  Harmonic  Analysis  option  makes  available  the  analysis  of  customer  load  though  the  50th  harmonic  order  while  the  Built-in  Comparator  option  provides  for  the  automatic  calculation  of  test  results  for  the  meters  and  standards  being  tested.
METER  AND  STANDARD  TESTING:  The  compact  light  weight  design  of  the  RD-20  makes  it  an  ideal  reference  standard  for  field  testing  applications.  The  RD-20  may  be  used  with  a  controlled  current  source  to  accurately  test  revenue  meters.  In  field  applications  the  RD-20  can  perform  a  single-phase  meter  accuracy  test  using  existing  service  load.  Pickups  to  sense  meter  disk  rotation  or  calibration  pulses  of  infrared,  visible  light,  or  KYZ  signal  plug  directly  into  the  RD-20.  The  RD-20  may  be  utilized  to  test  reference  standards  of  lesser  accuracy  and  is  also  an  ideal  standard  to  be  intergraded  within  a  meter  test  bench  where  lesser  accuracy  is  acceptable.
|