Product description |
|
Status |
Active |
|
Article number |
3651-0731 |
|
Ports |
1 x Detachable screw terminal, Status
1 x RS-422/485
1 x LC Duplex or LC Simplex, FX (Fibre) |
|
Description |
Point-to-Point Fibre Converter, RS-422/485 |
|
Warranty period |
5 Years |
|
Reliability prediction |
|
Service life, operating |
Operating, 10 year |
|
EMC (Electromagnetic Compatibility) |
|
EN 61000-6-1 |
Immunity residential environments |
|
EN 61000-6-2 |
Immunity industrial environments |
|
EN 61000-6-3 |
Emission residential environments |
|
EN 61000-6-4 |
Emission industrial environments |
|
EN 55022 |
Emission IT equipment, class A |
|
EN 55024 |
Immunity IT equipment |
|
FCC part 15 |
Class A |
|
EN 50121-4 |
Railway signalling and telecommunications apparatus |
|
IEC 62236-4 |
Railway signalling and telecommunications apparatus |
|
EMC specifications |
|
EN 61000-4-2, ESD |
Enclosure contact, ± 6 kV
Enclosure air, ± 8 kV |
|
IEC 61000-4-3, RF field AM modulated |
Enclosure:
10 V/m 80% AM (1 kHz), 80 – 800 MHz
20 V/m 80% AM (1 kHz), 800 – 1000 MHz
20 V/m 80% AM (1 kHz), 1400 – 2700 MHz |
|
ENV 50204, RF field 900 MHz |
Enclosure, 20 V/m pulse modulated 200 Hz, 900 ± 5 MHz |
|
EN 61000-4-4, fast transients |
Signal ports, ± 2 kV
Power ports, ± 2 kV |
|
EN 61000-4-5, surge |
Signal ports unbalanced, ± 2 kV line to earth, ± 2 kV line to line
Signal ports balanced, ± 2 kV line to earth, ± 1 kV line to line
Power ports, ± 2 kV line to earth, ± 2 kV line to line |
|
EN 61000-4-6, conducted RF immunity |
Signal ports, 10 V 80% AM (1 kHz), 0.15 – 80 MHz
Power ports, 10 V 80% AM (1 kHz), 0.15 – 80 MHz |
|
EN 61000-4-9, pulsed magnetic field |
Enclosure, 300 A/m, 6.4 / 16 μs pulse |
|
EN 61000-4-11, Voltage dips and interruption |
AC power ports:
10 & 5 000 ms, interruption
200 ms, 40% residual voltage
500 ms, 70% residual voltage |
|
EN 61000-4-16, Mains freq. 50 Hz |
Signal ports, 100 V 50 Hz line to earth |
|
SS 436 15 03, Mains freq. 50 Hz |
Signal ports, 250 V 50 Hz line to line |
|
EN 55022, radiated RF emission |
Enclosure, class B |
|
FCC part 15, radiated RF emission |
Enclosure, class B |
|
EN 55022, conducted emission |
AC power ports, class B
DC power ports, class A |
|
FCC part 15, conducted emission |
AC power ports, class B |
|
Safety |
|
Safety |
UL/CSA/IEC/EN 60950-1, IT equipment |
|
EN 60950-1, dielectric strength |
Signal port to all other isolated ports, 2 kVrms 50 Hz 1min
Power port to other isolated ports:
3 kVrms 50 Hz 1min
2 kVrms 50 Hz 1min (@ rated power < 60V) |
|
Climatic |
|
Temperature, operating |
–40 to +70°C (–40 to +158°F) |
|
Temperature, storage |
–40 to +70°C (–40 to +158°F) |
|
Humidity, operating |
5 to 95% relative humidity |
|
Humidity, storage |
5 to 95% relative humidity |
|
Enclosure |
|
Enclosure |
UL 94, PC / ABS, flammability class V-1 |
|
Dimensions (W x H x D) |
35 x 121 x 119 mm (1.37 x 4.76 x 4.68 in) |
|
Weight |
0.26 kg |
|
Degree of protection |
IP 21 |
|
Cooling |
Convection |
|
Mounting |
Horizontal on 35 mm DIN-rail |
|
Mechanical |
|
IEC 60068-2-6, vibration |
Operating:
7.5 mm, 5 – 8 Hz
2 g, 8 – 500 Hz |
|
IEC-60068-2-27, shock |
Operating, 15 g, 11 ms |
|
Interface specifications, power |
|
Rated voltage |
12 to 48 VDC and 24 VAC |
|
Operating voltage |
10 to 60 VDC and 20 to 30 VAC |
|
Rated current |
300 mA @ 12 V
150 mA @ 24 V
75 mA @ 48 V |
|
Rated frequency |
DC and 48 to 62 Hz |
|
Inrush current |
0.2 A²s |
|
Startup current |
1.0 Apeak |
|
Polarity |
Reverse polarity protected |
|
Redundant power input |
Yes |
|
Isolation to |
RS-485 and Status port |
|
Connection |
Detachable screw terminal |
|
Connector size |
0.75 – 2.5 mm² (AWG 18 – 13)
Connect the unit using at least 18 AWG (0.75 mm2) wiring |
|
Shielded cable |
Not required |
|
Interface specifications, status |
|
Port type |
Signal relay, changeover contacts |
|
Rated voltage |
Up to 48 VDC |
|
Operating voltage |
Up to 60 VDC |
|
Contact rating |
500 mA @ 48 VDC |
|
Contact resistance |
< 50 m Ohm |
|
Isolation to |
RS-485 and Power port |
|
Connection |
Detachable screw terminal |
|
Connector size |
0.2 – 2.5 mm² (AWG 24 – 13) |
|
Shielded cable |
Not required |
|
Interface specifications, RS-422/485 |
|
Electrical specification |
EIA RS-485, 2-wire or 4-wire twisted pair |
|
Data rate |
300 bit/s – 1.5 Mbit/s |
|
Data format |
9 – 12 bits |
|
Protocol |
Start-bit followed by 8-11 bits |
|
Retiming |
Yes |
|
Turning time |
One tbit
tbit = 1 / Baud rate (Baud rate in bit/s) |
|
Transmission range |
< 1200 m, depending on data rate and cable type (EIA RS-485) |
|
Settings |
120 Ohm termination and failsafe biasing 680 Ohm |
|
Protection |
Installation Fault Tolerant (up to ±60 V) |
|
Isolation to |
Status and Power port |
|
Connection |
Detachable screw terminal |
|
Connector size |
0.2 – 2.5 mm² (AWG 24 – 13) |
|
Shielded cable |
Not required |