Product description |
|
Status |
Discontinued |
|
Article number |
3641-1630 |
|
Ports |
12 x 10/100 Mbit/s (4 for bypass capability)
1 x 12 Mbit/s USB |
|
Description |
Managed EN50155 Backbone Routing Switch |
|
Warranty period |
5 Years |
|
EMC (Electromagnetic Compatibility) |
|
EN-50121-3-2 |
Railway applications – EMC: Rolling stock – Apparatus |
|
EN-50155 |
Railway applications, Approval/Compliance |
|
EMC specifications |
|
EN 61000-4-2, ESD |
Enclosure contact discharge immunity: ±6 kV
Enclosure air discharge immunity: ±8 kV |
|
IEC 61000-4-3, RF field AM modulated |
Enclosure RF immunity: 20 V/m, 80 – 2700 MHz |
|
EN 61000-4-4, fast transients |
Signal port immunity: ±2 kV
Power port immunity: ±2 kV |
|
EN 61000-4-5, surge |
Power port immunity:
±2 kV (L-E)
±1 kV (L-L) |
|
EN 50155:2001, surge |
Power port immunity:
±8.4 kV (L-E)
±8.4 kV (L-L) |
|
EN 61000-4-6, conducted RF immunity |
Signal port immunity:
10 V/m
0.15 – 80 MHz
Power port immunity:
10 V/m
0.15 – 80 MHz |
|
EN 61000-4-8, power frequency magnetic field |
Enclosure immunity:
300 A/m
0, 16.7, 50 Hz |
|
EN 61000-4-9, pulsed magnetic field |
Enclosure immunity: 300 A/m |
|
EN-50155, voltage dips and interruption |
Residual voltage 0%: 10 ms |
|
EN 50155, supply overvoltage and under voltage |
Overvoltage 140%: 100 ms & 1000 ms
Residual voltage 60%: 100 ms |
|
EN 55011, Limits: EN 50121-3-2,radiated emsission |
Enclosure measurement:
40 dBμV/m QP
30 – 230 MHz
47 dBμV/m QP
230 – 1000 MHz |
|
EN 55011, Limits: EN 50121-3-2, conducted emission |
Power port measurement:
99 dBμV QP
0.15 – 5 MHz
93 dBμV QP
5 – 30 MHz
Signal port measurement:
99 dBμV QP
0.15 – 5 MHz
93 dBμV QP
5 – 30 MHz |
|
Safety |
|
EN 60950-1, dielectric strength |
EN 60950-1, IT equipment |
|
Reliability prediction |
|
MTBF, operating |
MIL-HDBK- 217F,operating, 306.000 h |
|
Climatic |
|
Temperature, operating |
–40 to +70ºC (–40 to +158ºF) |
|
Temperature, storage |
–40 to +70ºC (–40 to +158ºF) |
|
Humidity, operating |
5 to 95% relative humidity |
|
Humidity, storage |
5 to 95% relative humidity |
|
Maximum surface temperature |
- |
|
Enclosure |
|
Dimensions (W x H x D) |
175 x 100 x 144 mm (6.88 x 3.93 x 5.66 inch) |
|
Weight |
2240 g |
|
Degree of protection |
IP 65 |
|
Cooling |
Convection |
|
Mounting |
Rear panel wall mounting |
|
Mechanical |
|
IEC 60068-2-6, vibration |
Operating:
7.5 mm, 5 – 8 Hz
2 g, 8 – 500 Hz |
|
IEC 60068-2-64, vibration |
Operating:
Vertical 1.0 m/s² Transverse
1.0 m/s² Longit. 1.0 m/s² |
|
IEC-60068-2-27, shock |
Operating:
15 g 11 ms, 3 x 6 chocks |
|
Interface specifications, power |
|
Rated voltage |
24 to 110 VDC |
|
Operating voltage |
16.8 to 143 VDC |
|
Rated current |
580 mA @ 24 VDC
140 mA @ 110 VDC |
|
Inrush current |
5 mA²s @ 24 VDC
22 mA²s @ 110 VDC |
|
Startup current |
600 mA @ 24 VDC
275 mA @ 110 VDC
(Power source capability) |
|
Polarity |
Reverse polarity protected |
|
Redundant power input |
No |
|
Isolation to |
All interfaces and chassis |
|
Galvanic connection to |
None |
|
Connection |
M12 A-coded male |
|
Connector size |
0.2 – 2.5 mm² (AWG 24 – 13) |
|
Shielded cable |
Not required |
|
Interface specifications, 10/100BaseTX |
|
Electrical specification |
IEEE std 802.3. 2000 Edition |
|
Data rate |
IEEE std 802.3. 2000 Edition |
|
Protocol |
- |
|
Duplex |
Full or half, manual or auto |
|
Circuit type |
SELV |
|
Transmission range |
100 m / 328 ft |
|
Isolation to |
All interfaces and chassis |
|
Galvanic connection to |
None |
|
Connection |
M12 D-coded |
|
Shielded cable |
Yes. Should also be separated from EMI disturbers |
|
Conductive housing |
Yes |
|
Miscellaneous |
- |
|
Number of ports |
12 |
|
Interface specifications, USB |
|
Electrical specification |
USB |
|
Data rate |
12 Mbit/s |
|
Protocol |
USB v2.0 |
|
Connection |
M12 A-coded female |
|
Isolation to |
All interfaces, but not to chassis
|