Automatic evaporation
ET3301 evaporation station is a fast, sample concentration for small volume. Easy to set up, without continuous monitoring. The adjustable bath temperature and nitrogen flow will shorter evaporation time.
User-friendly operation
The operator just place the sample, close the cover, set and turn on the nitrogen flow. The timer close the nitrogen flow and notify the operator when evaporation time end.
Flexible and efficient
ET3301 offer interchangeable vial rack can handle different sample volumes up to 60 samples. The vial size from 4mL to 35mL. The nitrogen flow channel is independently controlled for different evaporation time.
Save space and money
Backset evaporation technology, stable temperature water bath and adjustable nitrogen flow enhance evaporative performance.
compact size, no fume hood space is required, evaporated solvent pump by the exhaust fan and discharge through flexible gas tube
reduce operating time and operating costs
Increase the accuracy of the sample process
Improve laboratory efficiency
Handle more samples simultaneously
saves the operator time to monitor in the evaporation process
No vacuum and cooling facilities in require
Large LCD and push button allow the operator control and setup directly, LCD and buzzer to alert the operator for any event
Special design ventilation path reduce the condense and eliminate the cross contamination
6 individual timed nitrogen channels easy to handle the different types of samples
Before all process completed, the timer will pause when the top cover was opened and the timing system will continue after the top cover re-close
Application:
• Safety, food and beverage, residue analysis
• Environmental analysis
• Biological analysis
• Pharmaceutical drug test
Technical Specification
Number of sample
Number of channel |
Up to 60 vials
Up to 6 channels, 3 for standard, 10 nozzles/channel
|
Bath temperature
|
Ambient temperature ~ 95¡æ
|
Timing range
|
1-999 min.
|
Nitrogen source
Nitrogen flow
Nitrogen pressure control
|
Min. 60psi
Max.120psi
0 ~ 2L/min/ea
Manual adjust, digital display
|
Ventilation Port for evacuation
|
5cm (and additional 3cm) ID
|
Power requirements
|
220V 50Hz 1200Vac (optional 110V 60Hz )
|
Size
|
540W×350D×310H
|
Net Weight
|
25Kg
|
Shipping Weight
|
35Kg
|
Evaporation rate of the organic solvent
Solvent
|
Time
|
Dichloromethane / IPA / NH4OH
|
9 min
|
Hexane / ethyl acetate£¨75£º25£©
|
5 min
|
Hexane / ethyl acetate£¨50£º50£©
|
5 min
|
Dichloromethane
|
5 min
|
Methanol£¨98£º2£©
|
8 min
|
ET3301 Ordering Guide
Part # |
Description
|
|
|
I110001
|
10×75mm vial rack (4ml)
|
I110002
|
12×75mm vial rack (6ml)
|
I110003
|
13×100mm vial rack (10ml)
|
I110005
|
16×100mm vial rack (15ml)
|
I110006
|
16×125mm vial rack (19ml)
|
I110007
|
16×150mm vial rack (24ml)
|
I110008
|
20×150mm vial rack (35ml)
|
I110009
|
10×75mm vial 500 ea/box (4ml)
|
I110010
|
12×75mm vial 250 ea/box (6ml)
|
I110011
|
13×100mm vial 250 ea/box (10ml)
|
I110012
|
16×100mm vial 250 ea/box (15ml)
|
I110013
|
16×125mm vial 250 ea/box (19ml)
|
I110015
|
16×150mm vial 250 ea/box (24ml)
|
I110016
|
20×150mm vial 100 ea/box (35ml)
|
I110017
|
Nozzle cap, pk/30
|
I110018
|
Bath Keeper 200mL
|