Product description |
Status |
Active |
Article number |
3615-0030 |
Ports |
1 x 300 bit/s to 115.2 kbit/s, RS-232.
1 x SIM slot. |
Description |
GSM modem, GSM / GPRS |
Warranty period |
5 Years |
Standard compliance |
R&TTE |
Article 3.1b
EN 301 489-1, EN 301 489-7
Article 3.2
EN 301 489-1, EN 301 419-1, EN 301 511 |
Reliability prediction |
Service life, operating |
Operating, 10 year |
EMC (Electromagnetic Compatibility) |
EN 61000-6-2 |
Immunity industrial environments |
EN 55024 |
Immunity IT equipment |
EN 61000-6-3 |
Emission residential environments |
FCC part 15 |
Class B |
EN 50121-4 |
Railway signalling and telecommunications apparatus |
IEC 62236-4 |
Railway signalling and telecommunications apparatus |
EMC specifications |
EN 61000-4-2, ESD |
Enclosure contact, ± 6 kV
Enclosure air, ± 8 kV |
IEC 61000-4-3, RF field AM modulated |
Enclosure, 20 V/m 80% AM (1 kHz), 80 – 2000 MHz |
ENV 50204, RF field 900 MHz |
Enclosure, 20 V/m pulse modulated 200 Hz, 900 ± 5 MHz |
EN 61000-4-4, fast transients |
Signal ports, ± 2 kV
Power ports, ± 2 kV |
EN 61000-4-5, surge |
Signal ports unbalanced, ± 2 kV line to earth, ± 2 kV line to line
Signal ports balanced, ± 2 kV line to earth, ± 1 kV line to line
Power ports, ± 2 kV line to earth, ± 2 kV line to line |
EN 61000-4-6, conducted RF immunity |
Signal ports, 10 V 80% AM (1 kHz), 0.15 – 230 MHz
Power ports, 10 V 80% AM (1 kHz), 0.15 – 230 MHz |
EN 61000-4-8, power frequency magnetic field |
Enclosure, 100 A/m, 50 Hz, 16.7 Hz & 0 Hz |
EN 61000-4-9, pulsed magnetic field |
Enclosure, 1000 A/m, 6.4 / 16 ms 5 pos/5neg pulse in XYZ direction |
EN 61000-4-11, Voltage dips and interruption |
AC power ports:
10 & 5 000 ms, interruption
10 & 500 ms, 30% reduction
100 & 1 000 ms, 60% reduction |
EN 61000-4-16, Mains freq. 50 Hz |
Signal ports, 100 V 50 Hz line to earth |
SS 436 15 03, Mains freq. 50 Hz |
Signal ports, 250 V 50 Hz line to line |
EN 61000-4-29, voltage dips and interruption |
DC power ports:
10 & 100 ms, interruption
10 ms, 30% reduction
10 ms, 60% reduction
+20% above & –20% below rated voltage |
EN 55022, radiated RF emission |
Enclosure, class B |
FCC part 15, radiated RF emission |
Enclosure, class B |
EN 55022, conducted emission |
AC power ports, class B
DC power ports, class B |
FCC part 15, conducted emission |
AC power ports, class B |
Safety |
Safety |
EN 60950, IT equipment |
EN 60950-1, dielectric strength |
Signal port to other isolated ports, 2 kVrms 50 Hz 1 min
Power port to other isolated ports, 3 kVrms 50 Hz 1 min, 2 kVrms 50 Hz 1 min (@ rated power <60 V) |
Climatic |
Temperature, operating |
–25 to +50°C (–13 to +122°F) |
Temperature, storage |
–30 to +85°C (–22 to +185°F) |
Humidity, operating |
5 to 95% relative humidity |
Humidity, storage |
5 to 95% relative humidity |
Enclosure |
Enclosure |
UL 94, PC / ABS, flammability class V-1 |
Dimensions (W x H x D) |
34 x 123 x 121 mm (1.33 x 4.84 x 4.76) |
Weight |
0.2 kg |
Degree of protection |
IP 21 |
Cooling |
Convection |
Mounting |
Horizontal on 35 mm DIN-rail |
Mechanical |
IEC 60068-2-6, vibration |
Operating
7.5 mm, 5 – 8 Hz
2 g, 8 – 500 Hz |
IEC-60068-2-27, shock |
Operating, 15 g, 11 ms |
Interface specifications, power |
Rated voltage |
12 to 48 VDC |
Operating voltage |
10 to 60 VDC |
Rated current |
350 mA @ 12 VDC
150 mA @ 24 VDC
75 mA @ 48 VDC |
Rated frequency |
DC |
Inrush current |
0.05A2s |
Startup current |
0.75A peak |
Polarity |
Reverse polarity protected |
Connection |
Detachable screw terminal |
Connector size |
0.2 – 2.5 mm2 (AWG 24-12) |
Isolation to |
All other ports 3 kVrms 50 Hz 1 min |
Shielded cable |
Not required |
Interface specifications, RS-232 |
Electrical specification |
RS-232 V.24 |
Data rate |
300 bit/s – 115.2 kbit/s |
Data format |
7 or 8 data bits, Odd, even or no parity, 1 or 2 stop bits |
Protocol |
Transparent |
Retiming |
Yes |
Transmission range |
15 m / 49 ft |
Isolation to |
Power port 3 kVrms 50 Hz 1 min |
Connection |
9-pin D-sub female (DCE) and 5 pos Detachable screw terminal (DCE) |
Connector size |
Detachable screw terminal 0.2 – 2.5 mm2 (AWG 24 – 12) |
Shielded cable |
Not required |
Conductive housing |
Isolated to all other circuits |
Interface specifications, Antenna |
Frequency bands |
GSM900 TX 880 – 915 and RX 925 – 960 MHz
GSM1800 TX 1710 – 1785 and RX 1805 – 1880 MHz |
Data rate |
CSD: up to 14.4 kbit/s, GPRS: up to 85.6 kbit/s |
Connection |
SMA female, impedance: 50 ohm |
Isolation to |
Power port 3 kVrms 50 Hz 1 min |
Interface specification, SIM |
Electrical specification |
3 volts SIM supported |
Isolation to |
Power port 3 kVrms 50 Hz 1 min |